ESD fixtures for semiconductor test: material choices that pass qualification

Test sockets and wafer-handling fixtures fail qualification for three reasons — resistivity drift, outgassing and particulate. Here is how to close all three at once.

Industry Focus 6 min read
ESD fixtures for semiconductor test: material choices that pass qualification

Semiconductor customers do not buy a material, they qualify a fixture. The qualification usually turns on three things, and a grade can pass two of them and still be rejected.

The first is resistivity stability. A carbon-black loaded PEEK or PPS that measures 10 to the power 7 ohms on the day of moulding can drift an order of magnitude after a few hundred thermal cycles. Ask for the resistivity figure after cycling, not just the as-supplied data.

The second is outgassing. In a vacuum or a sealed test chamber, volatile compounds condense onto optics and contacts. Unfilled PEEK and PEI are among the lowest outgassing engineering plastics; heavily lubricated or plasticised grades are not. The third is particulate generation, which is largely a function of surface finish and edge quality rather than the polymer itself — which is why we machine these parts with polished flutes and deburr under magnification.

Need a material recommendation?

Send us the application and we will reply with two or three candidate grades and a price.

Ask an engineer
Share this article

2 comments

Leave a comment

Your e-mail address is not published.

Send us your drawing, get a price in 24 hours

Tell us the material, the size and how many pieces. If you are not sure about the material, describe the application and we will recommend one.

Request a quote Browse stock shapes