In the quoting traffic at our desk, the three words arrive interchangeably: “antistatic sheet”, “dissipative sheet”, “conductive sheet” — sometimes all three in the same sentence for the same part. They are not synonyms. They name three resistivity regimes, each built for a different electrical job, and each with a different way of failing when the wrong one is delivered. This note defines the three regimes, the standards that measure them, and the specification language that gets the right one onto the loading dock.
The three regimes, defined by numbers
Everything starts with surface resistivity, quoted in ohms per square, because for a tray, a worksurface or a machined fixture the charge you are managing sits on the surface. The widely used band boundaries are conventions rather than laws of physics, but they are stable enough to build a specification on:
| Regime | Surface resistivity | What it does | What it is for | Typical materials |
|---|---|---|---|---|
| Antistatic | 10^9 – 10^12 ohms | Prevents charge from building up in the first place | Packaging, film liners, general storage where nothing sensitive is handled directly | Migratory-additive ABS/PE, pink polyethylene-type packaging |
| Static dissipative | 10^6 – 10^11 ohms | Drains charge slowly and controllably | Workstations, trays, machined fixtures handling bare devices | Carbon-filled ESD POM, ESD ABS, ESD PEI |
| Conductive | < 10^5 ohms (often 10^2 – 10^5) | Drains charge almost instantly, behaves like a leaky metal | Shipping containers for already-shielded parts, grounding paths, EMI shielding | Carbon-loaded conductive POM, PEI, PPS grades |
Notice the overlap: 10^9 to 10^11 appears in both the antistatic and the loose end of dissipative. This is why the words alone are ambiguous and the numbers must be in the RFQ. Above 10^12 the material is an insulator — charge stays where it lands — and no amount of “antistatic” labeling fixes that.
What each regime is actually doing electrically
Antistatic in the strict sense is a rate property, not a resistance: the material does not attract or hold triboelectric charge. The classic mechanism is migratory additives — soap-like molecules that bloom to the surface and, with airborne moisture, form a thin conductive film that lets charge bleed away before it accumulates. Two consequences matter. First, the property depends on humidity: at 50% RH the sheet reads 10^10; in a dry winter hall or a desiccated cleanroom the same sheet drifts to 10^12 and does nothing. Second, the additive is on the surface and can be wiped off, so the property has a service life.
Dissipative is the middle regime and the one most machined ESD parts live in. The charge on a freshly handled device has to leave before the next event, but not so fast that the discharge pulse damages the device. Carbon-filled acetal, ABS and PEI achieve the 10^6 to 10^9 band with a conductive network through the bulk, so the property survives machining, washing and dry air. This is why nearly all machined fixtures, trays and component holders specify dissipative rather than antistatic.
Conductive below 10^5 is for charge that must leave immediately and for paths: interconnection between tray and ground, shielding enclosures, carriers where the part itself is already protected by shielding and the container’s job is to drain, not to cushion the discharge. The trap is putting a bare sensitive device into conductive packaging — a charged device touching a near-metal surface discharges through a sharp current spike that thin gate oxides do not survive.
The test standards behind the numbers
Three families of measurement cover the regimes. Surface and volume resistivity: ASTM D257 or the newer IEC 62631-3-1, with concentric ring electrodes on conditioned samples. Charge decay: ANSI/ESD STM11.31 and IEC 61340-2-3, measuring the time from +1000 V to 100 V — this is the functional number, and program documents built on ANSI/ESD S20.20 or IEC 61340-5-1 usually accept a decay under 2 seconds for work surfaces and items. Resistance to ground: ANSI/ESD STM4.1 for work surfaces, measuring from a point on the surface to a grounding point — relevant because a perfectly dissipative sheet bolted to an unpainted, oxidized frame can still fail in service. A specification that cites only ASTM D257 tells the supplier how to measure but not what the part must do; cite the decay target and the ground path as well.
Writing the specification line for each regime
For antistatic packaging-type applications: “Surface resistivity 10^9 – 10^12 ohms per ASTM D257 at 23 °C / 50% RH and at 12% RH after 48 h conditioning; no charge accumulation per IEC 61340-2-3, decay < 2 s at both humidity levels." The double-humidity clause is what separates a real antistatic spec from a laboratory promise, because the migratory mechanism collapses in dry air.
For dissipative machined parts: “Material carbon-filled ESD POM; surface resistivity 10^6 – 10^9 ohms per ASTM D257; volume resistivity < 10^8 ohm-cm; charge decay from 1000 V to 100 V < 2 s per ANSI/ESD STM11.31; properties to be maintained after machining and after cleaning with [named solvent]." The after-machining clause matters because the property must live through the pocket mill, and the after-cleaning clause because a migratory grade would silently fail it.
For conductive parts: “Surface resistivity < 10^5 ohms per ASTM D257; volume resistivity < 10^3 ohm-cm; resistance to groundable point < 10^6 ohms per ANSI/ESD STM4.1." For conductive grades the humidity dependence almost disappears — the carbon network dominates — so one condition is usually enough, but the resistance-to-ground line is the one that catches real problems.
Choosing the regime from the process, not the catalogue
Work backwards from two questions. What touches the surface? If bare sensitive devices rest on it directly, you want dissipative with a decay under 2 s — not antistatic, which may let charge linger, and not conductive, which discharges the device too violently. Is the part itself already protected? If the components travel inside shielding bags or handled with grounded wrist straps, the container can be conductive and cheap per kilogram of carbon. And is the environment dry? Below 30% RH, migratory antistatic grades should be off the table for anything critical; carbon-filled dissipative or conductive grades are the only honest choices. These three answers eliminate most of the misquotations we see, where “antistatic” was written because it sounded softer and safer than “conductive”.
One word of caution about the word itself
“Antistatic” is also used loosely by suppliers to mean “we put some additive in it”, with no number attached. When a quotation says antistatic and gives no resistivity band, ask for the number and the standard. The three regimes exist precisely so that a number, a standard and a conditioning condition can be written in one line — and once that line is in the RFQ, the word almost stops mattering.
Short answers
Antistatic vs conductive — which protects better?Neither in absolute terms. Antistatic prevents charging; conductive removes it instantly. Bare sensitive parts want dissipative in between; conductive protects shielding, not the bare part.
Can one sheet cover two regimes?A dissipative grade at 10^6 – 10^9 covers the tight dissipative band and, in dry conditions, drifts toward the antistatic band. A genuinely conductive grade below 10^5 cannot serve as dissipative — it is a different part of the ladder.
Which standard should the RFQ cite?ASTM D257 or IEC 62631-3-1 for resistivity, ANSI/ESD STM11.31 or IEC 61340-2-3 for decay, ANSI/ESD S20.20 or IEC 61340-5-1 as the program umbrella. Cite at least one resistivity standard and one decay standard.